1.
Sci Total Environ ; 716: 134959, 2020 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-31837845

RESUMO

Urban aerosol is a growing concern for people living within cities; aerosol have been implicated in many ill health conditions, including that of the lung and of the heart. Atmospheric potential gradient is a consequence of charge carried to the ionosphere through thunderstorms, and its value depends on highly electrically mobile ion concentrations, hence local conductivity of the air. Ions attach to aerosol in the atmosphere, reducing their mobility and therefore increasing the potential gradient, and so potential gradient measurements have been suggested as a proxy for aerosol measurements. Particle number count, size distribution and potential gradient were measured for two campaigns in Manchester, U.K., and one campaign in Bristol, U.K. Using a factor based on size distribution to account for preferential attachment at larger sizes provided the best relationship with potential gradient, but particle count alone showed a weaker, but similar relationship. The increase in particle count caused by annual bonfire and fireworks celebrations (November) was evidenced in both potential gradient and particle numbers. Daily regression or correlation did not show a consistent relationship. In the larger Bristol data set, increasing humidity led to a reduction of potential gradient, while increasing particle number led to an increase.

2.
Bratisl Lek Listy ; 116(11): 654-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26621161

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) is characterized by reductions in breathing amplitude during sleep caused by an obstructed or collapsed upper airway. The neutrophil to lymphocyte ratio (NLR) has been proposed as a novel biomarker for systemic inflammatory response. The aim of the present study was to evaluate the relationship between NLR and OSA. METHODS: The study population consisted of 195 consecutive patients with clinical suspicion of OSA. Full night polysomnography was performed for all patients. Patients with an apnea hypopnea index (AHI) ≥ 5 were considered to have OSA. NLR was calculated as the ratio of neutrophil count to lymphocyte count. RESULTS: While 130 patients (91 male, mean age: 49.9±9.8 years) had OSA, 65 patients (42 male, mean age: 48.7 ± 10.2 years) had normal findings according to AHI scores. Cardiovascular risk factors such as hypertension, hyperlipidemia, diabetes mellitus and smoking were more common in patients with OSA. Patients with OSA had significantly higher NLR than controls (1.87±0.80 vs 1.49±0.48, p=0.005). AHI score was significantly correlated with NLR (r=0.228, p=0.001). NLR and presence of hyperlipidemia were independent predictors of OSA (OR: 2.451, 2.850, p=0.001, 0.004, respectively). NLR of 1.62 or higher predicted OSA with a sensitivity of 56.2 % and specificity of 63.1 %. CONCLUSIONS: NLR was higher and also correlated with AHI score in patients with OSA which has not been reported previously. NLR more than 1.62 was an independent predictor of OSA. A simple, cheap white blood cell count may also give an idea about the presence and severity of OSA (Tab. 3, Fig. 3, Ref. 30).


Assuntos
Linfócitos , Neutrófilos , Apneia Obstrutiva do Sono/imunologia , Adulto , Idoso , Doenças Cardiovasculares/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Apneia Obstrutiva do Sono/complicações
3.
Bratisl Lek Listy ; 116(11): 659-61, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26621162

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) is characterized by reductions in breathing amplitude during sleep caused by an obstructed or collapsed upper airway. The neutrophil to lymphocyte ratio (NLR) has been proposed as a novel biomarker for systemic inflammatory response. The aim of the present study was to evaluate the relationship between NLR and OSA. METHODS: The study population consisted of 195 consecutive patients with clinical suspicion of OSA. Full night polysomnography was performed for all patients. Patients with an apnea hypopnea index (AHI) ≥ 5 were considered to have OSA. NLR was calculated as the ratio of neutrophil count to lymphocyte count. RESULTS: While 130 patients (91 male, mean age: 49.9 ± 9.8 years) had OSA, 65 patients (42 male, mean age: 48.7 ± 10.2 years) had normal findings according to AHI scores. Cardiovascular risk factors such as hypertension, hyperlipidemia, diabetes mellitus and smoking were more common in patients with OSA. Patients with OSA had significantly higher NLR than controls (1.87 ± 0.80 vs 1.49 ± 0.48, p=0.005). AHI score was significantly correlated with NLR (r=0.228, p=0.001). NLR and presence of hyperlipidemia were independent predictors of OSA (OR: 2.451, 2.850, p=0.001, 0.004, respectively). NLR of 1.62 or higher predicted OSA with a sensitivity of 56.2 % and specificity of 63.1 %. CONCLUSIONS: NLR was higher and also correlated with AHI score in patients with OSA which has not been reported previously. NLR more than 1.62 was an independent predictor of OSA. A simple, cheap white blood cell count may also give an idea about the presence and severity of OSA (Tab. 3, Fig. 3, Ref. 30).


Assuntos
Transtorno do Espectro Autista/sangue , Ocitocina/sangue , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Masculino
4.
Sci Total Environ ; 506-507: 201-16, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25460953

RESUMO

High-resolution measurements of gas and aerosols' chemical composition along with meteorological and turbulence parameters were performed over the Aegean Sea (AS) during an Etesian outbreak in the framework of the Aegean-GAME airborne campaign. This study focuses on two distinct Etesian patterns, with similarities inside the Marine Atmospheric Boundary Layer (MABL) and differences at higher levels. Under long-range transport and subsidence the pollution load is enhanced (by 17% for CO, 11% for O3, 28% for sulfate, 62% for organic mass, 47% for elemental carbon), compared to the pattern with a weaker synoptic system. Sea surface temperature (SST) was a critical parameter for the MABL structure, turbulent fluxes and pollutants' distribution at lower levels. The MABL height was below 500 m asl over the eastern AS (favoring higher accumulation), and deeper over the western AS. The most abundant components of total PM1 were sulfate (40-50%) and organics (30-45%). Higher average concentrations measured over the eastern AS (131 ± 76 ppbv for CO, 62.5 ± 4.1 ppbv for O3, 5.0 ± 1.1 µg m(-3) for sulfate, 4.7 ± 0.9 µg m(-3) for organic mass and 0.5 ± 0.2 µg m(-3) for elemental carbon). Under the weaker synoptic system, cleaner but more acidic air masses prevailed over the eastern part, while distinct aerosol layers of different signature were observed over the western part. The Aitken and accumulation modes contributed equally during the long-range transport, while the Aitken modes dominated during local or medium range transport.


Assuntos
Movimentos do Ar , Poluentes Atmosféricos/análise , Poluição do Ar/estatística & dados numéricos , Monitoramento Ambiental , Aerossóis/análise , Fenômenos Químicos , Mar Mediterrâneo , Conceitos Meteorológicos , Oceanos e Mares , Material Particulado/análise